SPOM basics
by oni-databaseDupes: 8Medium1500 kcal
Self-powered oxygen module: two electrolyzers feed eight duplicants and bank surplus hydrogen power.
Layout
Power
Generation+1600 W
Consumption+1320 W
Net+280 W
Two hydrogen generators outrun two electrolyzers plus four gas pumps while every machine runs; the module pays its own light bill.
Heat
Electrolyzer1500 kDTU/cycle
Hydrogen Generator4800 kDTU/cycle
Gas Filter0 kDTU/cycle
Net+6300 kDTU/cycle
Gas pumps shed nothing on paper here; the generator room wants a wall between it and your farms, not a lecture.
Materials
Raw Metals1650 kg
All Metals600 kg
- GasVentHighPressure — Mass not specified: constructionMaterialsRaw/massRaw are a symbolic array in the data plane