O₂

Petroleum boiler

by oni-databaseDupes: 8Hard2000 kcal

Crude from a capped oil well flash-boils straight to petroleum; twin turbines claw the heat back as power.

Layout

Power

Generation+4000 W
Consumption+2160 W
Net+1840 W

Two petroleum generators outrun the aquatuner, both gas pumps, the liquid pump and the oil well cap combined.

Heat

Petroleum Generator24000 kDTU/cycle
Steam Turbine4800 kDTU/cycle
Oil Well1200 kDTU/cycle
Liquid Pump1200 kDTU/cycle
Thermo Aquatuner0 kDTU/cycle
Net+31200 kDTU/cycle

The generator hall radiates most of this number by itself; the boiler room's real heat budget is the flash point, which no extracted field carries.

Materials

Any Buildable4800 kg
All Metals2100 kg
Refined Metals200 kg
  • SteamTurbine2Mass not specified: constructionMaterialsRaw/massRaw are a symbolic array in the data plane
  • PetroleumGeneratorMass not specified: constructionMaterialsRaw/massRaw are a symbolic array in the data plane

count x CONSTRUCTION_MASS_KG tier per building (const_table.json tiers); terrain (insulated boiler shell, mesh floor) is layout-only and excluded

Counts

Open in builder